Overview
-
-
Mini temperature controller with socket. -
-
With clear LED display for better readability. -
-
Wide temperature measuring range. -
-
Heating or cooling control. -
-
All parameters setting can be saved after short circuit. -
-
Directly power output. -
-
high Control precision 0.1 centigrade -
-
Can be used for domestic freezer, refrigerator,industrial chiller, steamer, industrial -
Parameters
|
|
|
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
|
|
|
|
|
|
| |
|
| |
|
|
NOTE:
-
-
The max current of output is 10A (110Vac/220Vac). In order to make sure the controller work under high performance condition. We recommend to use maximum power ≤ 800W when you use resistive load such as heating rod, heating pad, electric water heater etc. We recommend to use maximum power ≤ 275W when you use inductive load such as compressor , heat pump etc. -
-
-
The sensor can not put in the water for a long time, if you need that, please contact us. -
Package Content
-
-
1 x Thermostat -
-
1 x English Manual -
KT3008
Key Operation Instruction
-
-
In normal working status, screen display real time temperature. press UP key once. Screen display start temperature.press Down key once. Screen display stop -
-
temperature. -
-
Hold UP key. led flash,press UP or Down to change start temperature. -
-
Hold Down key. led flash, press UP or Down to change stop temperature. -
Operation Instruction
Cooling mode:
-
-
When set start temperature ≥ stop temperature, the controller will work in cooling mode.You can use cooler as load. -
-
-
For example, set start temperature 35 °C , stop temperatre 32 °C .Cooler work when temperature ≥ 35°C,Cooler stop when temperature≤32°C -
Heating mode:
-
-
When set start temperature ≤ stop temperature, the controller will work in heating mode.You can use heater as load. -
-
-
For example, set start temperature 45 °C , stop temperatre 60 °C .Heater stop when temperature ≥ 60°C,heater work when temperature≤45°C -
Reset:
In normal working status,hold UP and Down for 3S, the screen will display 888 to reset the controller.
Performance issues identification:
-
-
When the Led display LLL, check the sensor connected well or change the sensor. -
-
When the Led display HHH, the temperature is Beyond measurable range of sensor. -
KT3009
Key Operation Instruction
-
-
In normal working status, screen display real time temperature. press UP key once. Screen display start temperature.press Down key once. Screen display stop temperature. -
-
-
Press SET key. Led display P0, press UP or Down to switch code P0 P1 P2 P3. -