Note:
Due to rules of some shipping courier, parcels may not include batteries,otherwise it will not get through the custom.
specification:
Accuracy is specified for a period of one year after calibration and at 18°C to 28°C, with relative humidity < 75%.Accuracy specifications take the form of :± ([% of Reading]+[number of Least Significant Digits])
DC Voltage:
|
|
|
|
|
|
|
|
|
|
| |
|
| |
1000V |
|
|
Input Impedance: About 10M
Overload Protection:
the 200mV range: 250V DC/AC rms
other ranges: 1000V DC or 750V AC rms
AC Voltage:
Range | Resolution | Accuracy |
200mV | 100µV |
|
2V | 1mV | |
20V | 10mV | |
200V | 100mV | |
750V | 1V | ± (1.5% + 5) |
Input Impedance: About 10M
Frequency Range:
200V and 750V ranges: 40Hz - 100Hz
other ranges: 40Hz - 400Hz
Response: Average, calibrated in rms of sine wave
Overload Protection:
the 200mV range: 250V DC/AC rms
other ranges: 1000V DC or 750V AC rms
DC Current:
Range | Resolution | Accuracy |
2mA | 1µA | ± (0.8% + 2) |
20mA | 10µA | ± (1.5% + 2) |
200mA | 100µA |
|
20A | 10mA | ± (2.0% + 5) |
Overload Protection:
250mA/250V Fast fuse ( for protection for " mA " terminal inputs only )
( There is no fuse protection for " 20A " terminal inputs. )
Max. Allowable Input Current: 20A
( For inputs > 2A: measurement duration < 10 secs, interval > 15 minutes )
Max Voltage Drop: 200mV
AC Current:
Range | Resolution | Accuracy | |
2mA | 1µA | ± (1.2% + 3) | |
20mA | 10µA | ± (1.8% + 3) | |
200mA | 100µA | | |
20A | 10mA | ± (3.0% + 5) |
|
Frequency Range: 40Hz - 400H
Overload Protection:
250mA/250V Fast fuse ( for protection for " mA " terminal inputs only )
( There is no fuse protection for " 20A " terminal inputs. )
Max. Allowable Input Current: 20A
( For inputs > 2A: measurement duration < 10 secs, interval > 15 minutes )
Response: Average, calibrated in rms of sine wave
Max Voltage Drop: 200mV
Resistance:
Range | Resolution | Accuracy |
200Ω | 0.1 | ± (1.2% + 3) |
2kΩ | 1Ω | ± (1.0% + 2) |
20kΩ | 10Ω | |
200kΩ | 100Ω | |
20MΩ | 10kΩ | ± (1.5% + 2) |
200MΩ | 100kΩ | ± [ 5%×(reading - 10) + 10 ] |
Open Circuit Voltage: < 3.2V
Overload Protection: 250V DC/AC rms
Capacitance:
Range | Resolution | Accuracy |
2nF | 1pF | ± (5% + 10) |
20nF | 10pF |
|
200nF | 100pF | |
2µF | 1nF | |
200µF | 0.1µF |
Transistor hFE Test:
Range | hFE | Test Current | Test Voltage |
PNP & NPN | 0 - 1000 | Ib 10µA | Vce 2.8V |
Diode and Continuity:
Range | Description | Test Condition |
| The approx. forwardvoltage drop of thediode is shown on the display. | Open Circuit Voltage:about 2.8V |
| The built-in buzzer will sound if the resistance is less than about 30 . The buzzer may or maynot sound if the resistance is between 30 and 150 . The buzzer will not sound if the resistance is more than 150 . |
|