Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester EM5510
Note :
This package doesnot include batteries.
Due to new rules of China Post Air, parcels must not include batteries,
otherwise it will not get through the custom.
> This multimeter is 4000 count, 3 3/4-digit multimeter.
> It can be used to measure DC and AC voltage, DC and AC current,
resistance, capacitance, frequency, diode, temperature, continuity,
duty cycle and electromagnetic field radiation.
> It can be used as a test tool for environment and devices.
> It is a high-performance and versatile meter.
Safety Information >>>
This meter has been designed according to IEC-61010 concerning electronic measuring
instruments with a measurement category (CAT II 600V) and pollution degree 2.
GENERAL SPECIFICATION >>>
> Dimensions (W×L×T): 83×162×47 mm
DC Voltage >>>
Range | Resolution | Accuracy |
400mV | 0.1mV | ±(1.0%+5) |
4V | 1mV |
|
40V | 10mV | |
400V | 100mV | |
600V | 1V | ±(1.0%+5) |
Range | Resolution | Accuracy |
4V | 1mV | ±(1.0%+5) |
40V | 10mV | |
400V | 100mV | |
600V | 1V | ±(1.2%+5) |
DC Current >>>
Range | Resolution | Accuracy |
400uA | 0.1uA |
|
4000 uA | 1 uA | |
40mA | 10 uA | |
400mA | 100 uA | |
4A | 1mA | ±(1.8%+3) |
10A | 10mA | ±(2.0%+5) |
AC Current >>>
Range | Resolution | Accuracy |
400uA | 0.1uA |
±(1.5%+5)
|
4000 uA | 1 uA | |
40mA | 10 uA | |
400mA | 100 uA | |
4A | 1mA | ±(2.0%+5) |
10A | 10mA | ±(2.5%+5) |
RESISTANCE >>>
Range | Resolution | Accuracy |
400Ω | 0.1Ω | ±(1.0%+5) |
4kΩ | 1Ω |
|
40 kΩ | 10Ω | |
400 kΩ | 100Ω | |
4MΩ | 1kΩ | |
40MΩ | 10kΩ | ±(2.0%+5) |
FREQUENCY >>>
Range | Resolution | Accuracy |
10Hz | 0.01Hz | ±(1.0%+3) |
100Hz | 0.1Hz | ±(0.8%+3) |
1kHz | 1 Hz | |
10kHz | 10 Hz | |
100kHz | 100 Hz | ±(1.0%+3) |
200kHz | 1kHz | |
>200kHz | | Not specified |
CAPACITANCE(use Relative mode) >>>
Range | Resolution | Accuracy |
4nF | 0.001nF | ±(4.0%+5) |
40nF | 0.01nF | |
400nF | 0.1nF | |
4uF | 1nF | |
40uF | 10nF | |
100uF | 100nF | ±(8.0%+5) |
TEMPERATURE >>>
Range | Resolution | Accuracy |
-20℃~400℃ | 0.01℃ | ±1.5%±3℃ |
400℃~1000℃ | 1℃ | ±2.0%±3℃ |
DUTY CYCLE >>>
Range | Resolution | Accuracy |
1%~99% | 0.1% | 1Hz~10kHz:±(2.0%+5) |
>10kHz: not specified |
HUMIDITY(%RH) >>>
Range | Resolution | Accuracy |
30%~90% | 0.1% | --------------------- |
SOUND LEVEL(dB) >>>
Range | Resolution | Accuracy |
35~100dB | 0.1dB | --------------------------------- |
INTENSITY OF ILLUMINATION(Lux) >>>
Range | Resolution | Accuracy |
400x10 Lux | 1 Lux | --------------------------------- |
4000x10 Lux | 10Lux |
ACCESSORIES >>>
Test Lead; Temperature probe; Battery; Users Manual; Holster