AUTOOL LM120+ Digital Manifold Meter Air Conditioning Vacuum Gauge for Refrigeration HVAC Vacuum Pressure Temperature Tester
AUTOOL LM120 is an auxiliary instrument for the installation,testing and maintenance of refrigeration equipment such as air conditioners and cold storage.The instrument has double pressure test, dual temperature test (need test clip,not include), digital readout,multi-unit switching, multi-mode function and built-in refrigerant database.
UKOBD2 Provide top quality AUTOOL LM120+ Digital Manifold Meter Air Conditioning Vacuum Gauge for Refrigeration HVAC Vacuum Pressure Temperature Tester, if you need AUTOOL LM120+ Digital Manifold Meter Air Conditioning Vacuum Gauge for Refrigeration HVAC Vacuum Pressure Temperature Tester, or have any questions about AUTOOL LM120+ Digital Manifold Meter Air Conditioning Vacuum Gauge for Refrigeration HVAC Vacuum Pressure Temperature Tester, welcome to contact us.
Wholesale Top quality VAS6154, GM Tech2, VCM II For Ford, Porsche Piwis III, USB Link 2, Scania VCI3, CAN Clip, wiTech MicroPod 2, T300 key programmer, locksmith tools
images of AUTOOL LM120+ Digital Manifold Meter Air Conditioning Vacuum Gauge for Refrigeration HVAC Vacuum Pressure Temperature Tester
AUTOOL LM120 is an auxiliary instrument for the installation,testing and maintenance of refrigeration equipment such as air conditioners and cold storage.The instrument has double pressure test, dual temperature test (need test clip,not include), digital readout,multi-unit switching, multi-mode function and built-in refrigerant database.
1.AUTOOL LM120 uses high-strength engineering plastics and flexible non-slip silicone design, the whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability.Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation.Long-life valve switch, 1/4-inch standard interface design to ensure that the instrument's durability and versatility.
2.AUTOOL LM120 can measure double pressure (gauge pressure) at the same time, as well as dual temperature measurement (need test clip,not include), with automatic multi-unit pressure conversion, automatic conversion of temperature Celsius / Fahrenheit, to facilitate different needs.Built-in 89 kinds of refrigerant pressure-evaporation temperature database, also calculate the subcooling superheat, to facilitate direct reading of operating process data.Also it tests percentage of vacuum measurement; pressure leak measurement, leak time speed record.It is deserved to have this multi-functional, accurate and simply operated digital manifold let you do the job right.
Product specifications:
Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
Pressure test range: 0 Kpa – 6000 Kpa
Pressure test resolution: 1 Kpa
Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
Vacuum test: relative vacuum
Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
Vacuum test range: -101 Kpa – 0 Kpa
Vacuum test resolution: 1 Kpa
Temperature test unit: °C (Celsius), °F (Fahrenheit)
Temperature test range: -40°C–150°C (-40°F–302°F)
Temperature test resolution:
0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
Built-in 89 kinds of refrigerant NIST: According to American NIST standard
Power Supply: 4 X 1.5V (SIZE.AA / LR6) Battery not include
Dimensions: 170*110*50mm weight: 950g
EC/EN61010-1 safety standards for design and production.
2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).
3) The limit pressure is 10 Mpa (100 bar).
4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ).
The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ).
5) Please confirm the rated pressure value of the tested equipment before testing.
Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed hoses does not match the pressure requirement, you can use suitable replacements for testing.
6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.
7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring.
8) Please wear qualified protective equipment to protect user during testing.
9) Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases.
Packing list:
1x User Manual (in English)
2x Temperature Clip
3x Test Pipe
1x Suitcase
Battery not include