AUTOOL LM120 is an auxiliary instrument for the installation,testing and maintenance of refrigeration equipment such as air conditioners and cold storage.The instrument has double pressure test, dual temperature test (need test clip,not include), digital readout,multi-unit switching, multi-mode function and built-in refrigerant database.
AUTOOL LM120 Refrigeration Manifold Digital HVAC Cold Medium Vacuum Pressure Temp Car Air Conditioning Tester PK Testo DY517A is a one of our Car Air Conditioning Tester Tools, you can buy AUTOOL LM120 Refrigeration Manifold Digital HVAC Cold Medium Vacuum Pressure Temp Car Air Conditioning Tester PK Testo DY517A from ukobd2.com.
Wholesale Top quality VAS6154, GM Tech2, VCM II For Ford, Handy Baby II Car Key Chip Copier, CDP DS150
Pressure test: gauge pressure
Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
Pressure test range: 0 Kpa – 6000 Kpa
Pressure test resolution: 1 Kpa
Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
Vacuum test: relative vacuum
Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
Vacuum test range: -101 Kpa – 0 Kpa
Vacuum test resolution: 1 Kpa
Temperature test unit: °C (Celsius), °F (Fahrenheit)
Temperature test range: -40°C–150°C (-40°F–302°F)
Temperature test resolution:
0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
Built-in 89 kinds of refrigerant NIST: According to American NIST standard
Power Supply: 4 X 1.5V (SIZE.AA / LR6) Battery not included
1) The pressure measured by the digtal manifold pressure tester is gauge pressure.
2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).
3) The limit pressure is 10 Mpa (100 bar).
4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ).
The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ).
5) Please confirm the rated pressure value of the tested equipment before testing.
Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed
hoses does not match the pressure requirement, you can use suitable replacements for testing.
6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.
7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring.
8) Please wear qualified protective equipment to protect user during testing.
9) Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases.
1x Refrigerantion Digital Manifold Gauge
1x User manual (in English)
(Battery not included , Clips and tubes are not included for this version. If you need them please get the LM120+, or buy them seperatly.)